  • AC/DC Digital Clamp Tester (CE)

    M-270 - MULTI MEASURING INSTRUMENTS Co., Ltd.

    *Wide current measurements with tear drop type 55mmφCT up to 2000A.*True rms reading for ACA and ACV.*Data-hold and Auto power off function.*Additional AC/DC voltage, resistance, diode test, continuity check.*Auto zero adjustment for DC current offset.*Conform to IEC safety requirements.

  • 16-Channel VME Current Source & Analog Measurement Module

    V460 - Highland Technology, Inc.

    The V460 is a VME-based versatile source/measurement unit. It includes a programmable constant-current source, a precision programmable gain 16-bit analog-to-digital converter, and a 4-wire, 16-channel analog multiplexer. An internal microprocessor supervises channel scanning according to user loaded parameters, reporting sensor voltage drops or, for selected sensor types, engineering-unit data.

  • Digital LOOP/PSC/LOAD Tester

    1825 LP - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● Measures the voltage drop as if 16A was flowing between Line and Neutral.● Displays voltage without current (V at 0A).● Display voltage as if 16A flowing between Line and Neutral (V at 16A).● Loop test for L-E● PSC between L-N.● Single one smart push button operation; ON, Scroll through results and menus.● Checks wiring integrity (LEDs).● Auto off/auto ranging (software range).● Combined prospective short circuit current, loop and load tester.● Display can be customized for large orders.

  • Digital Multimeter

    DM500MAX - Power Probe Group, Inc.

    The DM500MAX is designed for harsh environments with a watertight gasket as the seams rotary switch, an input terminal, and battery cover to keep out dust, dirt, and splashing. They can also take shocks and drops, work anywhere from indoor to outdoor, and special designed LoZ(Low Impedance) feature to prevent false reading caused by ghost voltages.

  • Comparative Tracking Index (CTI)

    National Technical Systems

    Comparative tracking index (CTI) is used to assess the relative resistance of insulating materials to tracking. The CTI expressed as that voltage which causes tracking after 50 drops of 0.1 percent ammonium chloride solution have fallen on the material. The results of testing the nominal 3 mm thickness are considered representative of the material’s performance in any thickness.

  • Power Quality Meter

    Nexus 1450 - Amperis sl

    The Nexus 1450 is a powerful state-of-the-art power meter that provides high-precision electrical energy measurements and records waveforms. This equipment allows you to measure power quality and determine the reliability of electrical power. The Nexus 1450 meter allows you to see the reliability of the power circuit to determine the causes of failures, surges and voltage drops, and harmonics.

  • Air Core Electric Arc Furnace Reactors

    Hilkar

    Arc Furnace Reactors are serially connected reactors that are installed in the supply systems of arc furnace transformers to stabilize arc and limit the unstable arc furnace current and voltage drop which optimize their melting process. These buffer reactors are connected in series to the primary side of the furnace transformer. Typically these reactors are tapped coils and manufactured as per customer'stap requirements.

  • Portable Holiday Detectors

    Helmut Fischer AG

    Maximum safety with high voltage generation directly in the probe head and low-energy voltage according to ISO 2746Three instrument versions with different test voltage ranges:HV5: 0.8 5 kVHV20: 4 20 kVHV40: 8 40 kVIntuitive operation with menu navigation, rotary push switch and OLED displayExtensive selection of electrodesDisplay of the test voltage applied directly to the electrode Pore detection sensitivity: detection threshold settable to a voltage drop of 10, 20, 30 or 50 %Porosity detector switchable between static and dynamic thresholdBattery operation by means of a Li-ion battery with smart battery technology, a controller monitors the battery state permanently and avoids deep discharge

  • Handheld Digital Multimeter, 4.5 digit, up to 800 hours battery life

    U1281A - Keysight Technologies

    60,000 counts resolution on dual display0.025% basic DC voltage accuracy Longer battery life up to 800 hours Certified to IP 67 for dust and water protection Tested to withstand a 3-meter (10-ft) drop Programmable via USB (Download Programming Guide here)CAT III 1000 V/ CAT IV 600 V overvoltage protection

  • Non-Contact Voltage Tester

    NCVT-3 - Klein Tools, Inc.

    Provides non-contact detection of AC voltage.Detects 12 – 1000V AC with simultaneous visual and audible voltage indicators.Bright flashlight illuminates work area and may be used independent of voltage detection function.Visual LED bar graph indicates the presence of voltage – the higher the voltage sensed, or the closer to the voltage source, the more LEDs light up.Bar graph visual voltage indicator utilizes up to five vibrant LEDs for easy interpretation/viewing.Audible voltage indicator beeps at a greater frequency the higher the voltage that is sensed, or the closer to the voltage source.“Auto Power-Off” conserves and extends battery life.Screw-thread battery cap with O-ring ensures protection against dust and water ingress.Lightweight, compact tool with pocket clip provides convenient storage and quick access.IP67: Dustproof and waterproof.6.6 feet / 2 meter drop protection.CAT IV safety rating for 1000V.Conforms to CE requirements.

  • Automotive Battery Testers

    ELAK Private Ltd.

    ELAK Battery Testers are high-rate discharge testers. These testers impose a load on the battery, which is equivalent to that drawn by the starter motor from the battery, while cranking the engine. The tester studies the drop in battery voltage & indicates the condition of the battery if it is capable of starting the engine or not.

  • SureTest® Circuit Analyzer

    61-164 - IDEAL Industries, Inc.

    *Measures voltage drop under load**Hot and neutral conductor impedances*Estimates Load on Line (ELL) up to 15A*Tests GFCIs and EPDs for proper operation*Super-bright OLED display*High accuracies*True RMS*Line and peak voltage*Identifies proper wiring in 3-wire receptacles*Identifies false (bootleg) grounds*Tests without disturbing sensitive loads*Verifies isolated grounds (with 61-176 adapter)*2-year warranty*12A, 15A, 20A load tests

  • Dual Mobile Communications DC Source

    66309B - Keysight Technologies

    The Keysight Mobile Communications DC Source 663xx series offers several features ideal for testing wireless and battery powered devices. Excellent voltage transient response ensures maximum test-system throughput by minimizing device shutdowns due to significant voltage drops in the test wiring. Built-in advanced measurement system to accurately measure battery current drains when the device operates in different modes and a Keysight-developed feature that enables cellular telephone manufacturers to detect permanently and intermittently open-sense wire connections.

  • AC Voltage Detector

    Triplett Test Equipment & Tools

    high performance AC Voltage detector with adjustable sensitivity that has a wide measurement range of 25 to 1000ACV, Dual Color Tip to indicate low/high voltage, built-in flashlight and durable overmold. The high sensitivity allows it to detect low voltage AC wiring commonly found in doorbell circuits, thermostats, control circuits, and video surveillance camera power. The Sniff-It 3 is designed for industrial applications with its impact and drop resistance in a sleek ergonomic design, and the easy to use thumb wheel helps dial-in detection range. Includes (2) AAA batteries. CAT III safety rating.

  • Audio Multimeter

    AMM-1 - D'Amore Engineering llc

    The purpose of this tool is to enable the user to: Measure True Amplifier Power output into any load reactive or resistive Measure Common DC voltages Measure DC voltage drops during quick transients on cable runs or battery / charging systems Measure Impedance of speakers at any power or frequency from 20Hz - 1kHz (box rise) Measure Phase Difference between Voltage and Current into reactive loads (Power Factor) Find Tuning Frequency of subwoofer enclosures Tune subwoofer enclosures for maximum power transfer Measure AC Volts (amplifier output) Measure AC Amps (amplifier output)